Procedural characteristics of pulmonary vein isolation with high

Procedural characteristics of pulmonary vein isolation with high

5
(307)
Write Review
More
$ 9.00
Add to Cart
In stock
Description

The purpose of this study was to investigate the safety and efficacy of high-power short-duration (HP-SD) ablation compared to conventional ablation in patients with atrial fibrillation (AF). We enrolled consecutive 158 drug-refractory symptomatic AF patients (119 males, mean age 63 ± 10 years) who had undergone first radiofrequency pulmonary vein isolation (PVI). PVI was performed using the conventional setting (20–35 W) in 73 patients (Conventional group) and using the HP-SD setting (45–50 W) in 85 patients (HP-SD group). The rate of first pass isolation, remaining gaps after circumferential ablation, dormant conduction, and the radiofrequency application time in each pulmonary vein (PV) were compared between the groups. The first pass isolation ratio was significantly higher in the HP-SD group than in the Conventional group (81% vs. 65%, P = 0.027) in the right PV, but did not differ in the left PV. The remaining gaps were fewer in the right superior PV (4% vs. 21%, P = 0.001) and left inferior PV (1% vs. 8%, P = 0.032) areas, and the radiofrequency application time in each PV was shorter (right PV, 12.0 ± 8.9 min vs. 34.0 ± 31.7 min, P < 0.001; left PV, 10.6 ± 3.6 min vs. 25.7 ± 22.3 min, P < 0.001) in the HP-SD group than in the Conventional group. The use of the HP-SD setting might contribute to improve the first pass isolation rate and to shorten the radiofrequency application time in each PV.

Figure 3 from Redo Procedures in Patients with Paroxysmal Atrial

Frontiers Ablation index-guided high-power ablation for superior vena cava isolation in patients with atrial fibrillation

Takafumi ISHIDA, Professor, Fukushima Medical University, Fukushima, Department of Cardiovascular Medicine

Takafumi ISHIDA, Professor, Fukushima Medical University, Fukushima, Department of Cardiovascular Medicine

Significance of Contact Force on Esophageal Thermal Injury During Relative High-Power Short-Duration Ablation of Atrial Fibrillation

Hybrid Convergent Procedure for the Treatment of Persistent and

Pulsed-Field Ablation: A New, Highly Selective Catheter Ablation

JCM, Free Full-Text

The effect of high-power short-duration pulmonary vein isolation on PWPT—a predictor of paroxysmal atrial fibrillation

福島県立医科大学 循環器内科学講座 教室について 研究部門紹介 臨床研究 不整脈

Takafumi ISHIDA, Professor, Fukushima Medical University, Fukushima, Department of Cardiovascular Medicine